Connect Additional Parts to Design Object
Explanation
This activity is used to manually connect additional parts to a design object 
as opposed to automatically inheriting additional parts as described in the 
Inherit Additional Parts from Design Part activity. These additional parts 
are considered to be the material requirements for purchasing, maintenance, and 
fabrication and assembly activities. Individual requirements are identified by 
different quantity values registered along with the additional parts. 
Prerequisites
The object's class must allow additional parts as defined in its Class 
Relations. 
System Effects
An additional part is connected to a design object. If a valid project 
connection exists, these additional parts automatically insert records for  
ERMPL demands. 
Window
Additional Parts
Design Object
Related Window Descriptions
Additional Parts
Design 
Object/Additional Parts
Procedure
	- Open the Additional Parts window. 
- Click New.  
- In the Plant field, enter the plant owning the design object to 
	which the additional part will be connected. Use the List of Values to 
	select a suitable value. The user's default plant, if specified in the 
	User Settings dialog box, will be displayed by default. 
- In the Object ID field, enter the ID of the design object to which the 
	additional part will be connected. Use the List of Values to select a 
	suitable value.
- In the Design Part ID field, enter the ID of the design part/additional 
	part to be connected. Use the List of Values to select a suitable value. 
	Note: If the additional part is not found in the List of Values it may 
	not yet have been created or the design part class is not set up to serve as 
	a design part for the object's class according to the class' class 
	relations.
- By default, the values for the Spare Part Qty and Purchase
    Qty fields are set to 1. Adjust these values, as required.
- In the Fabrication Qty and Assembly Qty 
	fields, enter quantities as required.
- In the Fabrication Type and Supply Type 
	fields, select the suitable types, for the additional part being defined, 
	from the List of Values and list respectively.
- Click Save.
  Note: If the additional part has an Unavailable status, a system prompt
displays up asking if you want to add this additional part. Clicking  Yes adds the
	unavailable additional part, whereas clicking  No does not add the unavailable
additional part.
	
- Repeat the above steps to add more additional parts. 
Alternatively open the Design Object window, query for the design 
object 
for which the additional parts are being defined and perform steps 2-8 
with the exception of 4, as the additional parts will be created for the design 
object displayed 
in the header of this window.