Assign Parts to Maintenance Program
Explanation
This activity is used to assign valid serial parts to a maintenance program.
Prerequisites
  - Serial parts must have been defined.
- A maintenance program must have been defined. This maintenance program 
	must be in the Preliminary status.
- Template structures must have been defined if the Copy
    Parts From Template Structure option is to be used.
System Effects
  - The assigned serial parts are valid to use for the maintenance program.
     
- 
If the Copy Parts From Template Structure option is used, all serial parts 
belonging to the selected template structure will be assigned to the maintenance 
program.
- 
All existing revisions of the assigned serial parts are automatically added to 
the maintenance program. The assigned part revisions can be viewed in the 
Assign Part Revisions tab.
- 
Maintenance groups can be connected to the maintenance program.
Windows
Define
Maintenance Program
Parts Assigned To Maintenance Program
Related Window Descriptions
Define Maintenance
Program  
Define Maintenance Program/Assign Parts  
Copy Parts From Template Structure
 
Remove Part and Structure 
Procedure
 Note: 
	The following procedures can be performed using the 
Parts Assigned To Maintenance Program window as well.
Follow this procedure to assign a serial part to the 
maintenance program:
	- Open the 
	Define Maintenance Program 
	window and query (F3) for your maintenance program revision. 
- Click the 
	Assign Parts tab and 
	create a new record (F5).
- In the Part Number field, enter the part 
	number of the serial part which is to be assigned to the maintenance 
	program. Use the List of Values to select a value.
- If needed, enter the manufacturer of the serial 
	part in the Manufacturer Number field.
- If needed, enter the manufacturer's part identity 
	in the Manufacturer's Part No field.
- Save the record (F12).
Follow this procedure to assign a serial part to a 
maintenance program when the part number of the serial part is not known: 
	- Open the 
	Define Maintenance Program 
	window and query (F3) for your maintenance program revision. 
- Click the 
	Assign Parts 
	tab and 
	create a new record (F5).
- Enter the manufacturer of the serial part and the 
	manufacturer's part identity in the Manufacturer Number and 
	Manufacturer's Part No fields. Use the List of Values to select valid 
	values. Once these values are entered, the part number of the serial part 
	appears by default.
- You can also choose to directly enter the 
	manufacturer's part identity in the Manufacturer's Part No field. Use 
	the List of Values to select a value. Once the manufacturer's part identity 
	is entered, the manufacturer number and part number of the serial part 
	appear by default. 
- Save the record (F12).
Follow this procedure to assign serial parts to a 
maintenance program using the Copy Parts From Template Structure option:
	- Open the 
	Define Maintenance Program 
	window and query (F3) for your maintenance program revision. 
- Click the 
	Assign Parts 
	tab.
- Select the row that contains the part number that 
	was manually assigned to the maintenance program, right-click and then click 
	Copy Parts From Template Structure. The Copy Parts From Template 
	Structure dialog box opens.
- In the Template Part No field, the template 
	part number for the assigned part appears by default. If needed, click 
	List to select a different template part.
- In the Templ Rev field, enter the revision 
	number of the selected template part. Click List to select a valid 
	value.
- Select the Copy only Template Parts check box to copy template 
	parts in the selected template structure. There are no restrictions
    in the number of serial parts that can be copied to your maintenance
    program.
- Select the Copy Alternates check box to 
	copy alternates in the selected template structure.
- Click OK. 
When the Copy Parts From Template Structure option is used to assign 
serial parts, parts belonging to a template 
structure that is not required for the maintenance program may be copied as 
well. Use the following procedure to remove these serial part from the 
maintenance program:
	- Open the 
	Define Maintenance Program 
	window and query (F3) for your maintenance program revision. 
- Click the 
	Assign Parts 
	tab.
- Select the row that contains the template part 
	structure to remove, right-click and then click Remove Part and Structure. 
	The 
	Remove Part and Structure dialog box opens.
- The value in the Template Part No field 
	appears by default.
- In the Templ Rev field, enter the revision 
	number of the template part structure to be removed. Click List to 
	select a value.
- Click OK.