Configure Minimum Configuration
Explanation
Use this activity to set the minimum structure as indicated by the defined 
minimum configuration.
The minimum configuration is important for the building of a template 
structure. Through the minimum configuration you can specify the minimum 
structure that can be set operational. Consequently, when you disconnect a part 
that is included in the minimum configuration, the structure (vehicle) will be 
not be operational. If however you are required to disconnect a minimum 
configuration part from the structure, you need to replace it with an alternate 
before the structure can be made operational.    
Note that minimum configured parts in the structure of non-serialized parts 
will not affect the operational status of corresponding serials structures. Only 
the first level of non-serialized parts are considered in serials structures.
Prerequisites
  - A template structure with the Preliminary status must exist.
- The top part in the new structure must be defined before an import or copy 
	can be performed.
- A sub-part in the structure can only be included in the minimum 
	configuration if its higher assembly is part of the minimum configuration
System Effects
As a result of this activity, you will not be able to set the structure 
operational if one or more parts which are included in the minimum configuration 
of the template structure are disconnected.
Window
Serial 
Structure Template 
Template 
Structure Navigator
Related Window Descriptions
Serial Structure 
Template/Consist Of
Serial Structure Template/Multilevel
Template Structure 
Navigator/Consist Of 
Procedure
	- Open the 
	Serial Structure Template or the 
	Template 
	Structure Navigator window.
- In the Part Number field, query (F3) for your template structure.
- Click the 
	Consist Of tab. The Minimum Configuration 
	check box will be selected for the parts that are included in the minimum 
	configuration of your structure. 
 (If you need to move down the structure, select the row that contains the 
	part, right-click, and then click Next Level until the required parts 
	are displayed in the table of the tab.)
 Alternatively, you can choose to perform this procedure by using the 
	
	Serial Structure Template/Multilevel tab.
- To un-assign a part from the minimum configuration, clear the Minimum 
	Configuration check box for this part record OR select the row, 
	right-click, and then click Reverse Minimum Config to automatically 
	clear the check box.
 Alternatively, you can assign a part to the minimum configuration by 
	selecting the Minimum Configuration check box OR by selecting the 
	right mouse button option Reverse Minimum Config to automatically 
	select the check box.
- Save the record (F12).