Establish Maintenance Data for a Template Structure
Explanation 
This activity is used to establish operational 
parameters and Maintenance Group for the serial parts of a template structure. The different options available
in this activity are also 
available as separate activities that operate on single serial parts. This 
activity is useful when introducing a new type of material (i.e., new part revision, 
new product and model) or when modifying existing template 
structures. 
The following options are available within this 
activity:
  - Create new operational parameters for several or all
    the serial parts within a template structure.
- Create new Maintenance Group for several or all the
    serial 
  parts within a template structure.
- Establish or modify certain data elements for 
  operational parameters per maintenance group. The data elements that can be 
  specified are the maximum value and all the average operational values. In 
	addition, the sorting code can be given to indicate the order in which the 
	operational parameters are to be measured. The Due Info Sorting field 
	is used to indicate which 5 operational parameters should be displayed when 
	due information is presented. Sorting numbers 1, 
	2, 3, 4 and 5 must be used to indicate this.
Prerequisites
  - Serial parts need to exist.
- The serial parts for which you want to establish data must exist in a 
	serial structure template.  
- Basic data for the operational parameters must have been 
  defined.
- To create Maintenance Group for a template 
  structure, at least the primary operational parameter must have been defined for all
    the serial parts in the structure.
- To establish or modify operational parameters per 
  maintenance group, the maintenance group needs to exist for the serial parts in 
  the structure. 
System Effects
System effects of creating operational parameters are:
  - For life limited parts, it is possible to define life limits for the
    entered operational parameters.
- When adding new operational parameters, any maintenance
    group defined for the part is updated with the new operational parameter. 
- You can register operational log data for all of the
    serials belonging to a registered part number and maintenance group.
System effects of creating Maintenance Group are:
  - 
  Interval maintenance and maintenance plans can be 
  defined.
System effects of establishing or modifying operational 
parameters per maintenance group are:
  - You can register operational log data for all the serials belonging to a registered part number and maintenance group.  
Window
Establish 
Maintenance Data for Template Structures
Related Window Descriptions
Establish Maintenance Data for 
Template Structures
Procedure
Use the following procedure to create an operational 
parameter for serial parts within a template structure:
  - Open the 
	Establish Maintenance Data for 
	Template Structures window and query (F3) for the template structure 
	you want to work with.
- In the Oper Param list, select an operational 
	parameter.
- Select the Primary Oper Param check box, if 
	the selected operational parameter is to be the primary operational 
	parameter. Furthermore, select either the Time Parameter or 
	Cycle Parameter check box depending on whether this is to be the operational parameter for times 
	or cycles.
- Right-click and then click Spread Suggested Data to Structure. 
	Suggested values are updated on all the serial parts in the structure.
- The table (on the 
	Template 
	Structure tab) displays
      all the serial parts in the structure. You can modify the data for the selected operational parameter. For example, if one serial part 
	does not require the suggested values, you can manually remove 
	these values from the part.  
- To save the changes, right-click and then click Save Operational Parameters for Parts. As a result, all the serial parts 
	in the structure with operational parameter data will receive the new 
	operational parameter. If Maintenance Group exist for any of the serial 
	parts, the new operational parameter value will be updated on these Maintenance Group.  
Use the following procedure to create a maintenance 
group for serial parts within a template structure:
  - Open the 
	Establish Maintenance Data for 
	Template Structures window and query (F3) for the template structure 
	you want to work with.
- Enter an ID for the new maintenance group in 
	the Maint Group field. Enter a description for this maintenance group 
	in the Maint Group Description field. 
- In the Average Value Rule list, select an 
	average value rule.
- Select the Preferred Maint Group check box, 
	if the new maintenance group is to be the preferred maintenance group.
- Right-click and then click Spread Suggested Data 
	to Structure. Suggested values are updated on all the serial parts in the 
	structure. 
- The table (on the 
	Template 
	Structure tab) displays all the serial parts in the structure. You
      can modify the data for the new maintenance group. For example, if the new maintenance 
	group is not the preferred maintenance group for a serial part, you can clear the Preferred Maint Group check box for the part. 
- To save the changes, right-click and then click 
	Save Maintenance Group for Parts. As a result, all the serial parts in the 
	structure with maintenance group data will receive the new maintenance 
	group.  
Use the following procedure to establish or modify 
operational parameters per maintenance group for serial parts within a template 
structure:
  - Open the 
	Establish Maintenance Data for 
	Template Structures window and query (F3) for the template structure 
	you want to work with.
- In the Oper Param list, select an operational 
	parameter for which the data is to be updated.
- Enter relevant values in the Max Value, 
  Planned Average, Historical Average and Manual Average 
	fields.
- In the Sorting Code field, enter a sequence number to indicate the 
	order of the operational parameters when operational loggings are recorded.
- Optionally, in the Due Info Sorting field, enter a sorting to 
	indicate which 5 operational parameters should be displayed when due 
	information is presented, and the order in which these parameters should be 
	displayed.
- Right-click and then click Spread Suggested Data to Structure. 
	Suggested values are updated on all serial parts in the structure.
- The table (on the Template Structure 
	tab) displays all the serial parts in the structure. You can modify data for the operational parameter per maintenance group 
	settings. For example, if the suggested data is not relevant for one serial 
	part, these values can be manually removed from the part.
- To save the changes, right-click and then click Save Modified Operational Parameter Values. 
	As a result, all the Maintenance Group for all the serial parts in the structure 
	with operational parameter settings is updated. Note: Only Maintenance Group that have existing operational parameters will be 
	updated.  
Use the following procedure if the data to be 
established or modified applies to all serials in the structure and does not 
need to be adjusted on certain parts: 
  - Open the 
	Establish Maintenance Data for 
	Template Structures window and query (F3) for the template structure 
	you want to work with.
- If an operational parameter is to be created, 
	select an operational parameter from the Oper Param list. 
- Select the Primary Oper Param check box, if 
	the selected operational parameter is to be the primary operational 
	parameter. Furthermore, select either the Time Parameter or 
	Cycle Parameter check box depending on whether this is to be the operational parameter for times 
	or cycles.
- If a maintenance group is to be created, enter 
	appropriate values in the Maint Group, Maint Group Description 
	and Average Value Rule fields.
- Select the Preferred Maint Group check box 
	if the maintenance group is to be the preferred maintenance group.
- If you need to adjust operational parameter 
	settings per maintenance group, specify valid values in the Max Value,
	Planned Average, Historical Average, and Manual Average 
	fields. 
- Right-click and then click Spread and Save Suggested 
	Data to Structure. As a result, 
	
		
			- All the serial parts in the template structure 
			will receive the new operational parameter or the new maintenance 
			group. 
- All the Maintenance Group for the serial 
			parts in the structure that have operational parameter values will
              be updated.
Note: If by accident you select or type an incorrect value,  and then add the value on all
the parts in the table through the Spread Suggested Data to Structure 
option, simply select or type the correct value and use Spread Suggested Data to Structure 
 option again to update the table.