Connect Sample Frequency Trigger
Explanation
This activity is used to connect the defined triggers to
one or more data points.
  - A specific data point can be connected to none, one,
    or many triggers at the same time.
- A specific sample frequency trigger can be connected
    to none, one, or many data points at the same time.
- The defined triggers and the connection between the triggers and data 
	points can be modified only if the control plan is in the Created 
	status.
- The Acceptance Sampling trigger is 
	system-generated and connected to the data point when the acceptance sampling inspection code is used and 
	can only be connected to a data point with that inspection code.  
 
Prerequisites
  - The control plan template or
	control plan must be in the Created status to be
able to connect the data points to a sample frequency trigger.
- At least one sample frequency trigger must have been
    defined. 
System Effects
As a result of this activity, the data points will be
connected to the sample frequency triggers. Analyses will be created automatically according to the
triggers defined for each data point. 
Window
Control Plan Template
Control Plan -
Manufacturing
Control Plan -
Purchasing
Related Window Descriptions
Control Plan Template
Control Plan - Manufacturing
Control Plan - Purchasing
Connect sample
frequency trigger
Procedure
  - Open the 
	Control Plan 
	- Manufacturing
    window, and click the 
	Sample Frequency Trigger tab.
- Click the 
	Connect sub tab.  Data points, test operation descriptions, and defined
    triggers will appear automatically.
- To connect the data points to one or many triggers,
    select the appropriate check box.
- Save the information. 
Note: The same activity can be performed in the 
Control Plan Template
or Control
Plan - Purchasing. The Acceptance Sampling trigger is defined 
and connected automatically when the acceptance sampling inspection code is used 