Enter Analysis Results for Inventory Part
Explanation
Use this activity to enter analysis results for an inventory part.
This activity allows you to record the measure quality results against the
quality test plan (Control Plan) for an inventory part where required. 
You can change the status of a data point to Complete. Only data points in
Complete status are considered when creating control charts or calculating capability indices.
    Once the data point has this status, the results cannot be edited. You can also create a new control chart
if SPC is
    activated in the control plan.
When all
    data points for an analysis have been reported, you can change the status to 
Confirmed.
Once an analysis has been confirmed, the results cannot be edited.
This activity contains a Security Checkpoint which can be activated by an 
administrator. With an activated security checkpoint on a function you will have 
to authenticate yourself again in order to fulfill the function. Additionally, 
whenever a security checkpoint is successfully passed a security checkpoint log 
is written, creating an audit trail of what is done.
Prerequisites
This activity has the following prerequisites:
  - A Control Plan header and one or more control plan lines must exist. The
Control Plan must be in the Active status. 
- To be able to enter analysis results, an analysis 
    must exist in the Planned status. 
    
System Effects
As a result of this activity, results are entered for an inventory part.
Window
 
Analysis
Results
Related Window Descriptions
 Analysis
Results
Analysis
Procedure
  - If you just created the analyses, you are prompted to indicate
    whether you want to view the created analysis overview. If you click Yes, the 
	Analysis
    Results  - Inventory window opens. 
- If you are working on previously created analyses, open the Analysis 
	Results window and query for the part for which you want to enter 
	data.
- If the part is serial tracked and variable data type results need to be 
	entered, right-click on the header and click Enter Serial Numbers. 
	The Enter Serial Numbers dialog box is opened. Select the 
	Selected Serial No check boxes for the corresponding serial numbers of 
	the parts included in the analysis. Click OK. 
- If the part is lot/batch tracked, and if the corresponding lot/batch 
	number has not been filled in Lot/Batch No field in the header, then 
	enter a value in the Lot/Batch No field. Use the List of Values to 
	select a suitable value. 
- Optionally, in the Analysis Results header, select a 
	filter value for the Data Point Filter field to populate the analysis 
	according to the selected option.
- For data points defined as variables, select the Variables tab 
	and enter your results in the Result field. For serial tracked parts, 
	the serial number also needs to be entered in the Serial No field. 
	Use the List of Values to select a suitable value.
- For data points defined as attributes, select the Attributes tab 
	and enter your results in the Nonconformities (c/u) and/or the 
	Nonconforming (np,p) fields.
- Save the changes.
- To change the status to Complete, right-click and then click  Complete
    Registered Results. 
- To create a new control chart if SPC is activated in the control plan,
    right-click on the line and click  Create SPC Chart.
- To print a test instruction, right-click in the header and then click 
    Print Test Instruction. The test instruction includes all control plan
    lines.
- To add document text to any line, right-click and click  Document Text.
- To print a report of your results for any line, right-click and click 
    Print Data Sheet.
- To confirm a single analysis, right-click in the header of the analysis
    and then click  Confirm Registered Results. 
- To confirm multiple analyses, select one or more analysis in the 
	Analysis window, and then right-click and click  Confirm Registered
    Results.
- When the analysis results are confirmed, the values
    in the Variable Result Status and Attribute Result Status
    fields are calculated automatically.