Change Part Revision
Explanation
This activity is used to change the part revision of a serial. The change of 
a serial part revision can occur as a result of embodying a modification on the 
serial. Note however that a part revision can also be changed for serials that 
do no have a defined modification. Furthermore, this activity may need to be 
performed due to the configuration changes on a serial. 
If you choose to change the part revision for a serial that is installed in a 
structure, the list of valid parts, i.e., position alternates for the structure 
position and template alternates for the template, is used to define the new 
part revisions for the serial. However, if you choose to perform this activity 
for a serial that is not installed in a structure, the different configurations 
(templates) for the serial part is used to define the valid new revisions for 
the serial.
When the part revision of a serial is changed, there can occur differences in 
templates, such as, new structure positions or removed structure positions. If
empty or not installed structure positions exist in the serial 
structure but do not exist in the new template revision, these empty 
structure positions will be removed automatically when this activity is 
performed. If structure positions exist in the template structure which are not 
present in the serial structure, these structure positions will be added 
automatically to the serial structure as empty structure positions when 
performing this activity. Empty or not installed structure 
positions refer to the structure positions where expected serials or parts are 
missing from the serial structure.  
Prerequisites    
System Effects
	- The serial is defined with a new part revision.
- The operational condition of the serial is set to Non Operational. 
	You can now manually verify that the configuration of the serial is updated, 
	so that, you can use the serial.
- If a new structure position is added to the template as a result of a 
	part revision change, an empty structure position will be added 
	automatically to the serial structure as well.
- Empty structure positions in the serial structure that are not 
	present in the new template revision will be removed automatically.
- The due calculation for interval maintenance, modifications, post 
	maintenance checks, life limited parts and fault deferrals will run 
	automatically for the serial to calculate due dates and values.
Window
Serial Structure Information 
Serial 
Structures 
Related Window Descriptions
Change Part Revision - Step 
1 
Change Part Revision - Step 2
Change Part Revision - Step 3
Change Part Revision - Step 4
Serial Structure Information 
Serial Structure Information/Consist Of
Serial Structures 
Procedure
	- Open the 
	Serial Structure Information window and query (F3) for 
	your serial structure. 
- If you need to move down the structure, click the 
	Consist Of 
	tab, select the row that contains the part, right-click, and then click
	Next Level until the required serial part is displayed in the header 
	of the window.
- Right-click anywhere in the header and then click Change Part 
	Revision. The Change Part Revision 
	assistant will open.
- In the New Revision 
	field, enter the new part revision. Click List to select a valid value.
- Optionally, you can define a manufacturer part number for the new 
	revision in the New Manu. Part No field. Click List to select 
	a valid value.
- If you want to assign a maintenance program to the new part revision, 
	enter a value in the Maint Program ID field. Click List to 
	select a valid value.
- If a maintenance group is required for the new part revision, 
	enter a value in the Maint Group field. Click List to select a 
	value.
- If you want to disconnect the serial from the current maintenance 
	program, select the Disconnect Serial from Maint Program 
	check box. Note: This check box will only be available when valid 
	maintenance programs do not exist for the new part revision.
- Click Next.
- The second step of the assistant opens if the new part revision is to be 
	created for a serial that is not installed in a structure. Here you can 
	change the template structure for your new part revision.
- In the Template Part No field, click List to select the 
	template part for the serial structure template you want. Similarly, select 
	the appropriate revision and structure position for this template part in 
	the Templ Rev and Structure Position fields.
- Click Next.
- In the third step of the assistant, you can update the child parts which 
	are defined in the structure of your new part revision.
- In the 
	Structure Position field, set the correct structure position for the 
	selected template structure. Click List to select the value.
- Click Next.
- In the fourth step of the assistant, you can select 
	the access groups that will have access to the new part revision of the 
	serial.
- The Implement For check box is selected by 
	default. You need to clear this check box for the access groups that will 
	not have access to the new part revision.
- Click Finish.
Note: This procedure may be performed using the 
Serial Structures