Connect Maintenance Program to Serial
Explanation
This activity is used to connect a maintenance program 
to a serial. If a valid active maintenance program is defined for the part 
number and revision of the serial, you need to connect the maintenance program 
to the serial before you can set the serial to either the In Operation or
Out Of Operation status for the first time.
If access control is established for parts and serials, 
you can only work with the serials to which you are granted access. Likewise, if 
access control is established for maintenance programs, you can only view and 
connect the maintenance programs to which you have access. Access control is 
established by setting up access groups with valid users and assigning the 
applicable access group to the part or maintenance program to which access 
should be restricted. 
Prerequisites
	- A maintenance program that is valid for the part number, revision and 
	maintenance group of the serial must have been defined. This maintenance 
	program must be in the Active status.
- You need to have access to the serial and 
	maintenance program you wish to work with. 
System Effects
As a result of this activity, maintenance programs are connected to the 
serials on which it will be performed.
Window
Serial 
Structure Information 
Serial Structures 
Serials
Vehicles
Define Maintenance Program
Related Window Descriptions
Change 
Maintenance Program On Serial - Step 1 of 3 
Serials in structure lacking 
maintenance programs - Step 2 of 3
Update values for interval 
maintenance on given serial - Step 3 of 3 
Serial 
Structure Information 
Serial 
Structure Information/Consist Of
Serial 
Structure Information/Multilevel  
Serial Structures 
Serials 
Vehicles 
Define 
Maintenance Program/Affected Serials
Procedure
Follow this procedure to connect a maintenance program to a serial that is in 
the Planned For Operation status:
	- Open the Serial Structure Information 
	window or the Serials window.
- Populate (F2) or query (F3) for the necessary serial.
- Click the General tab if you are 
	working in the Serial Structure Information window.
- In the Maint Program field, enter the maintenance program for the 
	serial. Use the List of Values to select a valid value.
- Save the information (F12).
Follow this procedure to connect a maintenance program 
to a serial by using the Change Maintenance Program On Serial 
assistant:
	- Open any one of the following windows or tabs 
	depending on your work flow:
	
		-  Serial Structure Information 
		
- Serial Structure Information/Consist Of
- Serial Structure Information/Multilevel
- Serial Structures
- Serials 
- Vehicles
- Define Maintenance Program/Affected 
		Serials.
	- Populate (F2) or query (F3) for the necessary serial.
- Right-click and click Change Maintenance Program. The 
	Change Maintenance Program On Serial assistant opens.
- In the New Maint. Prog field, enter the ID of the maintenance 
	program you want to connect to the serial. Click List to select a 
	valid value.
- If you want to change the maintenance group of the 
	serial, click List in the New Maint Group field to select and 
	enter the new maintenance group for the serial.
- Select the Change maintenance program for all serials in structure 
	check box if you want to update all serials in the structure with the new maintenance program.
- Select the Change maintenance group for all serials in the structure 
	check box if you want to update all serials in the structure with the new 
	maintenance group.
- Click Next.
- In the Serials in structure lacking maintenance 
	programs assistant step you can enter maintenance program information 
	for the serials in the selected structure.
- Select one of the query options to filter the serials for which you wish 
	to update maintenance program information. The table will list serials based 
	on the query selection.
- Select one of the spread options to enter or extend the maintenance 
	program information to the listed serials.
- If you have chosen to extend the maintenance program and maintenance 
	group to all listed serials, ensure the following information is entered 
	correctly:
	
		- In the New Maint Prog field, enter the new maintenance 
		program that is to be extended to the listed serials. Click List to 
		select a valid value.
- If the maintenance group is to be updated, enter the new maintenance 
		group in the New Maint Group field. Click List to select a valid 
		value.
	- Click Spread to extend the information to the listed serials. 
	Make adjustments if necessary, and then click Save. Click Spread 
	and Save if you want to extend and save the information immediately.
- If you have chosen to enter the maintenance program and maintenance 
	group directly in the table, enter the new maintenance program and 
	maintenance group in the New Maint Prog field and New Maint Group 
	fields found in the table. Click Save to save the information.
- If you have chosen to extend the maintenance program information that 
	was entered manually, use one of the options listed in step 13 to save the 
	information, i.e., Spread, Save, and Spread and Save.
- Click Next (for serials in either the In Operation or 
	Out Of Operation statuses) or click Finish.
- In the Update values for interval maintenance on given serial 
	assistant step you can enter or change the start values for the interval 
	maintenance of a serial(s) in the structure. This is useful for instance when the intervals for the maintenance code 
	on the old maintenance plan are different to the intervals on the new 
	maintenance plan and it is necessary to adjust the interval maintenance 
	values accordingly. The upper table displays the interval maintenance for 
	the primary operational parameters while the lower table displays all 
	secondary operational parameters corresponding to the primary operational 
	parameters.
- In the Value at Maintenance field, enter or change the total 
	operational value for the part and serial number for which you want to 
	change interval maintenance values. Note: The following conditions 
	apply: 
	
	
		- If the value in this field does not match the maintenance interval 
		in the maintenance plan the system displays a message. 
		
- The value in this field cannot exceed the value after overhaul for 
		the maintenance triggering operational parameters unless the maintenance 
		code has the calculation rule set to Special Case. In this case 
		the value cannot exceed the value total of the serial. 
		
- When a value is entered in this field, values for the fields 
		Maint Date and Correction Value are suggested automatically 
		only if the value in the lowest interval for the maintenance code 
		exceeds either the value total (when the calculation rule is set to 
		Special Case) or the value after overhaul (Inspection, Overhaul and 
		Replacement). 
	- In the Value Total field, enter the total operational value of 
	the serial at the date of maintenance. 
	
- Click Save to save your changes. 
	
- Click Finish to close the assistant. 
Follow this procedure to connect a valid active 
maintenance program to one or more affected serials:
	- Open the Define Maintenance Program 
	window.
- Populate (F2) or query (F3) for the active 
	maintenance program.
- Click the Affected Serials tab to 
	view all serials affected by this maintenance program.
- Select the serial record, right-click and then 
	click Set Maintenance Program.
- Verify that the connected maintenance program is 
	shown in the Maint Program ID, Maint Program Revision and 
	Maint Program Description fields for the serial record.