Create New Serial From Inventory and Remote
Explanation
This activity is used to create a new serial. All the serials
received into inventory, which are not defined as serials, belonging to either
IFS/Vehicle Information Management (IFS/VIM) or IFS Maintenance, can be defined
as a VIM serial in the 
Serials from Inventory window.
The serials that have been defined in remote inventories and then transferred to
a table in IFS/VIM, will also be visible in this window.
 These serials
might later be used in a VIM serial structure in connection with a work order.
When you enter a serial number, you have to enter values
that will update the 
Part Serial window with information
on the new serial.
All access groups assigned to the serial part can be
viewed on the 
Serial Structure Information/Access tab. If the serial is
access controlled, only the users assigned to the access groups that have the Has
Access check box selected can view and update information on the
serial.
When a new serial is created, the following will occur
in relation to the Access Control feature:
  - The serial will receive the access groups assigned
    to the template structure to which the serial belongs.
  
- If the new serial is defined within a structure, the
    serial will inherit the serial access groups from the topmost serial of the
    structure. If the serial is not installed in a structure, it will receive
    access defined for the part number and revision of the serial.
  
- If the parent of the new serial does not have a
    serial number,  the serial will inherit the access from the nearest
    parent that has a serial number in the structure. If the parent parts in the structure
    does not have a serial number, the serial will inherit the
    access defined for the part number and revision of the serial.
Prerequisites
  - The serial part number must be defined as a IFS/VIM serial part.
- The part must exist as a purchase part, and have at least one
    supplier
    defined.
- The new serials must be received into inventory and
    should not
    exist as VIM objects or equipment objects.
- The new definition of the serials in the 
	Part Serial window, must have the value  In Inventory or In
    Current Position, and the Eng Part Revision field must have a valid value
    defined.
- The new serials must be received from remote inventories and should not 
	exist as VIM objects. 
System Effects
  - New serials will be ready to use in VIM 
	serial structures. Before the serial can be installed in a structure it must 
	be issued from inventory.
- All access rights defined for the selected serial
    will be updated on the 
	Serial Structure Information/Access tab.
- Serials that do not have defined access groups can
    be viewed by all users.
- The access rights for the serial can be updated by
    using the right mouse button options on the Serial Structure Information/Access
    tab.
Window
Serials 
from Inventory 
Related Window Descriptions
Serials from
Inventory 
Serial Structure Information  
Serial Structures 
Serial Structure Information/Access  
Procedure
To create a new VIM serial part
from the serials that are either received into inventory or defined in remote
inventory. (They do not belong to
either IFS Maintenance or IFS/VIM.)
  - Open the 
	Serials From Inventory
    window. Populate (F2) or query (F3) for the part number for which you want to create a
    serial.
- Select the row, right-click and then click Create
    Serial.
 The 
	Create Serial From Inventory and Remote
    dialog box will open.
- Enter a value in the Part Revision field.
    Click List to select a value.
- Optionally, if an active maintenance program exists
    for the selected serial, you can enter a value in the Maint Program ID
    field. Click List to select a value. When a value is entered in this
    field, the values for Maint Program Revision and the Maint Program
    Description fields appear automatically. To view all the maintenance
    programs regardless of the maintenance group in the List of Values, remove
    the default value in the Maint Group field before selecting a value
    in this field. 
- In the Maint Group field, the default
    maintenance group will be displayed automatically. Click List to select a
    different maintenance group.
- In the Workshop  field the default workshop ID will be displayed automatically when the dialog box is opened.
    Click List to select a different workshop.
- Select the Set Out Of Operation check box if
    you want the created serial to be set out of operation. When a
    serial is created, the operational condition will be set to Planned For
    Operation by default.
- Enter the manufacturer number and the manufacturer part
    number for the selected serial. Enter values in the Manufacturer
    Number and the Manufacturer Part Number fields respectively. Click List
    to select suitable values.
- Enter the current location of the selected serial
    in the Location Code field. The default location ID will appear
    automatically when the dialog box is opened. Click List to select a
    value.
- Select a value from the Ownership list for
    the current ownership of the selected serial. This field cannot be updated
    for serials in the 
	Part Serial window.
- Enter a value in the Owner Org. field if the
    selected serial is a vehicle part. Also, enter the ID of the vehicle
    part in the Vehicle ID field.
- Click OK.
You can view the serial you created in the above window
in the Serials window.
To update the access groups for
the newly created serial
  - Open the 
	Serial Structure Information window,
    and query (F3) for the part serial number you created in the above
    procedure.
  
- Click the 
	Access tab. All the access
    groups inherited by the selected serial will appear on this tab. The Has Access
    check box will be selected for the access
    groups that currently have access to the serial.
  
- To either select or clear the Has Access
    check box, the following right mouse button options must be used,
  
    - Revoke Access Group For Serial - Select
      this option if you want to clear the Has Access check box, and
      thereby deny access to the new serial by the selected access group.
    
- Grant Access Group for Serial - Select this
      option if you want to select the Has Access check box, and thereby
      grant access to the new serial by the selected access group.
Note: The data on this tab can only be updated
  for the serials that are disconnected from a structure, and for the topmost serial