Unlock Serial
Explanation
This activity is used to unlock a top serial and its belonging structure. When a 
serial belonging to a structure is locked it is not possible to carry out any 
operations on the serial, except for the completion of running tasks. 
Information on the serial can be viewed even if the serial is locked.
Note: When a serial is locked, the Locked check box will be selected for the given
    serial in the Serial Structure Information/General tab and the
    Locked for Update check box will be selected in the Serials window. 
Prerequisites
	- A serial structure that is locked needs to exist. 
System Effects
  - The serial and its belonging structure is
    unlocked.
- It is possible to carry out operations on the
    serials in the structure.
- An active maintenance program is connected
    to the serial.
- All due calculations for the serial will be run to calculate due dates 
	and values.
Window
Serial Structure Information
Serials  
Related Window Descriptions
Unlock Serial  
Serial Structure Information/General
Serials  
Procedure
Option 01:
  - Open the  
	
	Serial Structure Information window.
- In the Part Number field, query (F3) for your serial that is locked.
- Click the General tab.
- Right-click on the tab, point to Status and
    click Unlock. The 
	Unlock Serial dialog
    box will open.
- In the table of this dialog box, all serials in the
    structure that have obsolete maintenance programs connected will be
    displayed, along with serials that do not have maintenance programs defined
    when the serial was locked.
- Click Set Program to automatically connect
    the new valid active maintenance program revision to all serials in the
    structure with obsolete maintenance programs connected. You can also click List
    by placing the cursor on the Maint. Program ID field to select a
    suitable active maintenance program ID. Note: In the list all active
    maintenance programs that the serial is connected to will be displayed.
- For locked serials that do not have maintenance
    programs registered, in the Maint Program ID field click List to
    select a valid active maintenance program.
- When valid maintenance programs are defined for all
    serials displayed in the table of this dialog box it will be possible to
    close the dialog box.
- Click OK to close the dialog box and unlock
    the serial and its structure. The serials in the structure will also be
    updated with the selected active maintenance program.
Option 02:
  - Open the 
	Serials window and
    query (F3) for the serial that is locked.
- Select the row that holds the part number of the
    locked serial right-click, point to Status and click Unlock.
    This will open the 
	
	Unlock Serial dialog box.
- Continue with steps 5 - 9 detailed in option 01 of
    this procedure.
Option 03:
  - Open the  
	Define Maintenance Program
    window and query (F3) for your maintenance program. You can also create a
    maintenance program (F5) and connect parts, part revisions and Maintenance Group to this maintenance program in the 
	Preliminary status.
- Click the  
	Affected Serials tab.
- Select the row that holds the part number of the
    locked serial, right-click, point to Status and click Unlock.
    This will open the 
	
	Unlock Serial dialog box.
- Continue with steps 5 - 9 detailed in option 01 of
    this procedure.