Configure Data Collection
Explanation
All the available processes in Warehouse Data Collection can be configured in 
the Data 
	Collection Configuration window. For each process, it is possible to 
create several configurations that can be accessed via the Warehouse Data 
Collection menu. To learn more about the configuration possibilities, see the 
Warehouse Data Collection Configuration About description. To learn more about 
the specific process behavior, see the Warehouse Data Collection Process About 
description.   
Prerequisites
This activity has no specific prerequisites.
System Effects
The options below can be 
enabled and configured depending on the customer demand on the process. When the configuration is created and configured, 
the scanning client running the process will behave according to those settings.
	- The enterprise explorer scanning client can be configured to show the 
	media pane and the width of the columns in the scanning client. The font 
	sizes can also be adjusted for the description and input field.
- The lifespan for the configuration can be set both for active and 
	completed sessions.
- The session settings for Confirm Execution, Reset 
	Session on Process Error, Process Completion 
	Action, 
	Subsequent Process ID and Subsequent Configuration ID can be set.
- The data items can be configured in several ways, using the following 
	columns: Input Order, Default 
	Value, Use Fixed Value, Hide Line, 
	Hide All Previous, Loop Start, 
	Loop End, Use Automatic Value, 
	List of 
	Values, Use Subsequent Value and Subsequent Data Item ID.
- For each data item, it is also possible to configure data item details 
	that will be shown in the scanning client directly after the data item value 
	has been entered. The order in which the data item detail will be shown can 
	also be configured.
- Process specific details can be enabled.
- The process configuration can be made accessible for the specified 
	companies, sites and users.
- The process configuration can start different 
	subsequent processes depending on a control data item.
Window
Data 
Collection Configuration
Data 
Collection Process
Related Window Descriptions
Data Collection Configuration
Data Collection 
Configuration/General
Data Collection 
Configuration/Items
Data Collection 
Configuration/Details
Data Collection 
Configuration/Valid for Companies
Data Collection 
Configuration/Valid for Users
Data Collection 
Process/Subsequent Process Details 
Data Collection Process
Data Collection 
Process/Items
Data Collection 
Process/Feedback Items
Data Collection 
Process/Details 
Procedure
Configure the valid companies, sites and users in the Data 
	Collection Configuration window.
	- Either populate or query for the process configuration. 
	
- Click the Valid For Companies tab. 
	
- Add a company. 
	
- Select the Valid for All Sites check box to enable all sites on 
	your company to have access to the configuration. 
	
- Click the Valid for Users tab. 
	
- Select the Valid for All Users check box to enable all users on 
	your company to have access to the configuration.
- Save. 
Configure the input order of the data items in the
Data 
	Collection Configuration window.
	- Either populate or query for the process configuration. 
	
- Right-click and then click Edit to change the status to 
	Editable. 
	
- Click the Items tab. 
	
- The top table displays the available data item IDs that can be entered in 
	the scanning process. 
	
- Change the input order column for one of the the data items and save. The order for the 
	other data items are recalculated.
Configure default values for the data items in the
Data 
	Collection Configuration window.
	- Either populate or query for the process configuration. 
	
- Right-click and then click Edit to change the status to 
	Editable. 
	
- Click the Items tab. 
	
- Enter a value in the Default Value field and save.  
	
- In the Use Fixed Value field,
	select Never in the enumeration.   
	
- Save. Right-click and then click Release to change the status to
	Released. 
	
Configure fixed values for the data items in the
Data 
	Collection Configuration window.
	- Either populate or query for the process configuration. 
- Right-click and then click Edit to change the status to 
	Editable. 
- Click the Items tab. 
- Enter a value in the Fixed Value column for the data item that 
	should have a fixed value.
- In the Use Fixed Value
	field, select Always 
	in the enumeration.  
- Save. Right-click and then click Release to change the status to
	Released. 
Note: The Use Fixed Value field can also 
be set to When Applicable for a number of data items, serial number for 
example. If Use Fixed Value is set to When Applicable and Fixed 
Value is set to "*" for the serial number data item it means that "*" will be 
automatically committed in the scanning client for a non-serial-traced part.   
Configure the hide functionality for the data items in the
Data 
	Collection Configuration window.
	- Either populate or query for the process configuration.
- Right-click and then click Edit to change the status to 
	Editable. 
	
- Click the Items tab. 
	
- Set  the Hide Line field to Always 
	for the data item that should be hidden in the information table of the 
	scanning client. 
- Save. Right-click and then click Release to change the status to
	Released. 
	
Note: The Hide Line field can also be set 
to When Fixed Value if the data item should only be hidden in the 
information table of the scanning client when a fixed value is used. 
Configure the Hide All Previous functionality for the data items in the
Data 
	Collection Configuration window.
	- Either populate or query for the process configuration.
- Right-click and then click Edit to change the status to 
	Editable. 
	 
	
- Click the Items tab. 
	 
	
- Select the Hide All Previous check box. 
	This will hide all previous data items and item details (except the ones 
	added to the previous data item) in the information table of the 
scanning client.
- Save. Right-click and then click Release to change the status to
	Released. 
	 
	
Configure using automatic values for the data items in the
Data 
	Collection Configuration window.
	- Either populate or query for the process configuration.
- Right-click and then click Edit to change the status to 
	Editable. 
	
- Click the Items tab. 
	
- Select the Use Automatic Value check box for the 
	data item for which a value can be given automatically.
- Save. Right-click and then click Release to change the status to
	Released. 
Configure the list of values for the data items in the
Data 
	Collection Configuration window.
	- Either populate or query for the process configuration.
- Click the Items tab. 
	
- In the List of Values field, select any of the values in the 
	enumeration; On, Off, Forced or Auto Pick.
- Save. 
Configure the subsequent data item ID for the data items in the
Data 
	Collection Configuration window.
	- Either populate or query for the process configuration.
- Right-click and then click Edit to change the status to 
	Editable. 
	
- Click the Items tab. 
	
- For the data item that should keep the entered data between the sessions, 
	enter the subsequent data item ID where the data should be displayed 
	as default.
- Change the Use Subsequent Value to fixed for the corresponding data item 
	ID.
- Save. Right-click and then click Release to change the status to
	Released. 
Configure loop start for the data items in the
Data 
	Collection Configuration window.
	- Either populate or query for the process configuration.
- Right-click and then click Edit to change the status to 
	Editable. 
	
- Click the Items tab. 
	
- Select the Loop Start check box for the data item 
	that should be the loop start.
- Save. Right-click and then click Release to change the status to
	Released. 
Configure loop end for the data items in the
Data 
	Collection Configuration window.
	- Either populate or query for the process configuration.
- Right-click and then click Edit to change the status to 
	Editable. 
	 
	
- Click the Items tab. 
	 
	
- Select the Loop End check box for the data 
	item that should be the loop end.
- Save. Right-click and then click Release to change the status to
	Released.  
Configure the camera-enabled for the data items in the Data Collection 
Configuration window.
	- Either populate or query for the process configuration. 
- Right-click and then click Edit to change the status to 
	Editable. 
- Click the Items tab. 
- Select the Camera-Enabled check 
	box. 
- Save. Right-click and then click Release to change the status to
	Released. 
Configure the item detail ID for the data items in the
Data 
	Collection Configuration window.
	- Either populate or query for the process configuration.
- Click the Items tab. 
	
- Select the data item that should have a data item detail ID.
- Create a new record in the lower table and select a data item detail ID 
	from the list of values.
- Save. 
Configure the subsequent process ID and configuration ID for the process 
configuration in the Data 
	Collection Configuration window.
	- Either populate or query for the process configuration.
- Right-click and then click Edit to change the status to 
	Editable. 
	
- Click the General tab. 
	
- Click the Process Completion Action list and select Create New Session.
- In the  Subsequent Process ID and Subsequent Configuration ID 
	fields, 
	enter the process configuration that should be started directly after the 
	selected one is completed in the scanning client.
- Save. Right-click and then click Release to change the status to
	Released. 
Configure scanner client settings for the process configuration in the
Data 
	Collection Configuration window.
	- Either populate or query for the process configuration.
- Right-click and then click Edit to change the status to 
	Editable. 
	
- Click the General tab. 
	
- Select the Enable Media Pane check box to enable media to be shown in 
	the scanning client.
- Enter the column width for the left column in the scanning client 
	table by entering the amount of pixels in the Data Item Description Column 
	Width field.
- Configure the input description font size by entering the size in the 
	Font Size field.
- Configure the input font size by entering the size in the Input Field 
	Font Size field.
- In the  Subsequent Process ID and Subsequent Configuration ID 
	fields, 
	enter the process configuration that should be started directly after the 
	selected one is completed in the scanning client.
- Save. Right-click and then click Release to change the status to
	Released. 
Configure the scanning session lifespan for the process configuration in 
the Data 
	Collection Configuration window.
	- Either populate or query for the process configuration.
- Right-click and then click Edit to change the status to 
	Editable. 
	
- Click the General tab. 
	
- In the Remove Active Sessions Older Than and Remove 
	Completed Sessions Older Than fields, enter the amount of days for which 
	the session 
	should be kept in the database for the background job.
- Save. Right-click and then click Release to change the status to
	Released. 
Configure process specific details for the  process configuration 
in the Data 
	Collection Configuration window.
	- Either populate or query for the process configuration.
- Right-click and then click Edit to change the status to 
	Editable. 
	
- Click the Details tab. 
	
- Select the Enabled check box for the process 
	specific detail that should be enabled.
- Save. Right-click and then click Release to change the status to
	Released. 
Configure subsequent process details 
in the Data 
	Collection Configuration window.
	- Either populate or query for the process configuration.
- Right-click and then click Edit to change the status to 
	Editable. 
	 
	
- Click the Details tab. 
	 
	
- Enter a value in Subsequent Control Data Item 
	ID field. This is the data item that will control the subsequent 
	processes.
- Click the Subsequent Process Details 
	tab.
- Enter the data item values and the subsequent 
	processes and configurations in the upper part of the tab.
- Enter the related data item and subsequent data 
	item in the lower part of the window.